![image.png](https://static.wixstatic.com/media/6b3186_89d75e5c29c34f7f8415a28ea273a92c~mv2.png/v1/crop/x_0,y_13,w_332,h_245/fill/w_306,h_226,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/image.png)
UL2464
Rating : 80 deg C, 300 Vac, Cable flame.
Use : Internal wiring or external interconnection of electronic equipment.
![image.png](https://static.wixstatic.com/media/6b3186_c40b797ba6034ca0ac94815aef8846c0~mv2.png/v1/crop/x_0,y_13,w_332,h_245/fill/w_306,h_226,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/image.png)
UL2725
Rating : 60 or 80 deg C, 30 Vac, Horizontal flame.
Use : Internal wiring of electronic equipment in Class 2 systems only.
![image.png](https://static.wixstatic.com/media/6b3186_895dcdaa79534b0a9a0a5345d07778b1~mv2.png/v1/fill/w_277,h_226,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/image.png)
UL20276
Rating : 60 or 80 deg C, 30 V ac, Cable Flame on construction A, Horizontal flame on construction B.
Use : Construction A: Internal wiring or external interconnection of electronic equipment in Class 2 circuits only. Construction B: Internal wiring of electronic equipment in Class 2 circuits only.
![image.png](https://static.wixstatic.com/media/6b3186_74bd1e19068f4171a1bc5cd5c38906e8~mv2.png/v1/crop/x_0,y_13,w_332,h_245/fill/w_306,h_226,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/image.png)
UL2095
Rating : 80 deg C, 300 Vac,
Horizontal flame.
Use : Internal wiring of electronic equipment and appliances. Tags may indicate the following: "600 volts Peak for Electronic use only".
![image.png](https://static.wixstatic.com/media/6b3186_3dc1246309184912b737f5b39eb92f94~mv2.png/v1/crop/x_0,y_13,w_332,h_245/fill/w_306,h_226,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/image.png)
UL2919
Rating : 80 deg C, 30 Vac, Cable flame.
Use : Internal wiring or external interconnection in Class 2 Circuits of electronic computers and electric business machines.
![image.png](https://static.wixstatic.com/media/6b3186_7619571da526482eb86331aea7a30c22~mv2.png/v1/fill/w_277,h_226,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/image.png)
UL2835
Rating : 60 deg C, 30 Vac, Cable flame for Use No. 1B and 2B, Horizontal flame for Use No. 1A and 2A.
Use : Use No. 1A:, Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.; Use No. 1B:, CABLES - using 30 mils or greater jacket thickness only: External .....
![1007.png](https://static.wixstatic.com/media/6b3186_cae2d4f4c2184c4abb0a4de74356971d~mv2.png/v1/crop/x_0,y_9,w_250,h_185/fill/w_305,h_226,al_c,lg_1,q_85,enc_avif,quality_auto/1007.png)
UL1007
Rating : 80 deg C, 300 Vac,
Horizontal flame.
Optional - 60 deg C or 80 deg C Oil.
Use : Internal wiring of appliances. Tags may indicate the following: 600 V Peak - For Electronic Use Only.
![2463.png](https://static.wixstatic.com/media/6b3186_6a1c2fe21e50448e98ddebdba15e1676~mv2.png/v1/crop/x_0,y_9,w_250,h_185/fill/w_305,h_226,al_c,lg_1,q_85,enc_avif,quality_auto/2463.png)
UL2463
Rating : 80 deg C, 600 Vac, Cable flame.
Use : Construction A: Internal wiring of X-ray Equipment, or in the internal or exteral interconnection of electronic equipment. Construction B: External interconnection of electronic equipment in abuse areas, such as X-ray Equipment and Business Machines.
![20949.png](https://static.wixstatic.com/media/6b3186_63ff5327ba9846e9bd95e38f8d96a04d~mv2.png/v1/fill/w_280,h_226,al_c,lg_1,q_85,enc_avif,quality_auto/20949.png)
UL20949
Rating : 105 deg C, 600 Vac,
Cable flame.
Use : Internal or external wiring of electronic equipment.